Legionella Disease (Legionnaires Disease)

Legionnaires Disease or Legionella Disease was first identified following a large outbreak of pneumonia among people who attended an American Legion Convention in Philadelphia in 1976. A previously unrecognised bacterium was isolated from lung tissue samples which was subsequently named Legionella pneumophila. It is normally contracted by inhaling Legionella bacteria, either in tiny droplets of water (aerosols), or in droplet nuclei (the particles left after the water has evaporated) contaminated with Legionella, deep into the lungs. There is evidence that the disease may also be contracted by inhaling Legionella bacteria following ingestion of contaminated water by susceptible individuals. Person to person spread of the disease has not been documented. Initial symptoms of Legionnaires’ disease include high fever, chills, headache and muscle pain. Patient may develop a dry cough and most suffer difficulty with breathing. About one third of patients infected also develop diarrhoea or vomiting and about half become confused or delirious. Legionnaires’ disease can be treated effectively with appropriate antibiotics. The incubation period is between 2-10 days (usually 3-6 days). Not everyone exposed will develop symptoms of the disease and those that do not develop the ‘full blown’ disease may only present with a mild flu-like infection.

Legionella Bacteria

Infection with Legionella bacteria can be fatal in approximately 12% of reported cases. This rate can be higher in a more susceptible population, for example, immunosuppressed patients or those with underlying disease. Certain groups of people are known to be higher at risk of contracting Legionnaires’ disease, for example, men appear more susceptible than women, as do those over 45 years of age, smokers, alcoholics, diabetics and those with cancer or chronic respiratory or kidney disease. On average there are approximately 200-250 reported cases with approximately 12% fatalities.

Legionnaires Disease Prevention - ACOP L8

The Health and Safety Commission announced in April 1989 its intention to take statutory action to strengthen existing legislation and guidance on the control of Legionnaires disease. The Approved Code of Practice (ACoP) 'The prevention or control of Legionellosis (including Legionnaires’ disease)'associated with the Health and Safety Executive guideline HS(G)70 - The control of Legionellosis including Legionnaires Disease was approved by the secretary of State for Employment on the 10th of April 1991 and became effective on 15th of January 1992. It has since been amended in 1995 to include where applicable, references to the COSHH regulations (Rev. 1994) and place greater emphasis on the need for regular Risk Assessment reviews.

HS(G)70 has now been replaced by the updated document L8 which came into effect on the 8th of January 2001. The scope of a Legionellosis Risk Assessment is defined in the ACoP L.8 paragraphs 18-38. The ACoP applies whenever water is stored or used in a way that may create a reasonably foreseeable risk of Legionellosis. In particular it applies to the following plant:

  • Cooling tower systems
  • Evaporative condensers
  • Hot and cold water systems non-domestic premises.
  • Hot and cold water systems where the occupants are particularly susceptible. (i.e. Health/Care Premises).
  • Humidifiers and air washers, spa baths and pools.
  • Other plant and systems containing water which is likely to exceed 20°C and which may release a spray or aerosol (i.e. a cloud of droplets and/or droplet nuclei) during operation or when being maintained.

Whilst this is not an exhaustive list, it does identify those systems which are most likely to cause infection. Consideration should also be given to other systems, which can release spray or aerosol during operation, maintenance and testing.